International Journal of Engineering Technology and Scientific Innovation
Submit Paper

Title:
CAUSES AND METHODS OF ELIMINATING THE DISTURBANCES WHICH OCCUR IN THE NETWORK WHEN SUPPLYING A CONSUMER FROM AN UPS USING VIRTUAL INSTRUMENTATION

Authors:
Claudiu Nicola, Marcel Nicola, Viorica Voicu, Maria Cristina Nitu, Sebastian Popescu

|| ||

National Institute for Research, Development and Testing in Electrical Engineering - ICMET Craiova, Romania

MLA 8
Nicola, Claudiu, et al. "CAUSES AND METHODS OF ELIMINATING THE DISTURBANCES WHICH OCCUR IN THE NETWORK WHEN SUPPLYING A CONSUMER FROM AN UPS USING VIRTUAL INSTRUMENTATION." IJETSI, vol. 2, no. 3, 2017, pp. 652-670, ijetsi.org/more2017.php?id=54.
APA
Nicola, C., Nicola, M., Voicu, V., Nitu, M. C., & Popescu, S. (2017). CAUSES AND METHODS OF ELIMINATING THE DISTURBANCES WHICH OCCUR IN THE NETWORK WHEN SUPPLYING A CONSUMER FROM AN UPS USING VIRTUAL INSTRUMENTATION. IJETSI, 2(3), 652-670. Retrieved from http://ijetsi.org/more2017.php?id=54
Chicago
Nicola, Claudiu, Marcel Nicola, Viorica Voicu, Maria C. Nitu, and Sebastian Popescu. "CAUSES AND METHODS OF ELIMINATING THE DISTURBANCES WHICH OCCUR IN THE NETWORK WHEN SUPPLYING A CONSUMER FROM AN UPS USING VIRTUAL INSTRUMENTATION." IJETSI 2, no. 3 (2017), 652-670. http://ijetsi.org/more2017.php?id=54.

References
References
[1] R. Singh and A. Singh, "Aging of distribution transformers due to harmonics," Harmonics and Quality of Power (ICHQP), 2010 14th International Conference on, pp. 1-8, 2010.
[2] IEEE Recommended Practice and Requirements for Harmonic Control in Electric Power Systems, IEEE 519/2014.
[3] Normativ privind limitarea regimului nesimetric deformant in retelele electrice - Aprobat cu Decizia nr.76/1994- Regia Autonoma de Electricitate Renel, PE 143/94.
[4] A. Ortiz, C. Gherasim, M. Manana, C. J. Renedo, L. I. Eguiluz, and R. J. M. Belmans, "Total harmonic distortion decomposition depending on distortion origin," IEEE Transactions on Power Delivery, vol.20, pp. 2651-2656, 2005.
[5] L. Bajan, "Total current harmonic distortion analyses of industrial UPS's with SCR input converter working in redundant mode," Electrical Machines (ICEM), pp. 1- 4, 2010.
[6] M. H. Abbas, "Total harmonic distortion analysis simulation,", Power System Technology, vol.3, pp. 1631-1634, 2000.
[7] N. Stanciu, D. Stanescu, P. Postolache, and W. Szabo, " Voltage sags and Total Harmonic Distortion monitoring in power systems. A case study," International Symposium on Advanced Topics in Electrical Engineering (ATEE), pp. 1-6, 2000.
[8] D. Kottick, Power Quality monitoring system - voltage dips, short interruptions and flicker, Elect. Power Qual. & Utilisagion Magazine vol. 3, issue 2, August, 2008.
[9] I. V. Blagouchine and Eric Moreau, "Analytic Method for the Computation of the Total Harmonic Distortion by the Cauchy Method of Residues," IEEE Transactions on Communications, vol.59, pp. 2478-2491, 2011.
[10] X. Hu and Y. Liu, "Principle and running maintenance on UPS power supply," Electronic and Mechanical Engineering and Information Technology,vol.9, pp. 4721-4723, 2011.
[11] F. Vatra, A. Poida, and C. Stanescu, "Data system for the monitoring of power quality in the transmission substations supplying big consumers," International Conference on Electrical Power Quality and Utilisation, pp. 1-5, 2007.
[12] D. Rusinaru, L. G. Manescu, M. Merfu, and P. Postolache, "Power quality general levels in distribution networks," International Conference on Harmonics and Quality of Power (ICHQP), pp. 58-62, 2014.
[13] R. Alves et al., "Development of an Electrical Power Quality Monitor based on a PC," 35th Annual Conference of IEEE, Industrial Electronics IECON '09, pp. 3649- 3653, 2009.
[14] A. N. Gowda, D. L. Girijamba, G.N. Rishika, S. D. Shruthi, and S. Niveditha, "Control4 Smart Home System using LabVIEW," International Journal of Engineering Science and Innovative Technology (IJESIT), vol. 2, Issue 3, pp.200-205, May 2013.
[15] M. C. Ni?u, C. Nicola, V. Voicu, S. Popescu, M. Nicola, "Analysis using virtual instrumentation of perturbations induced in the network to supply a consumer from a UPS," in Applied and Theoretical Electricity (ICATE), 6-8 Oct. 2016.
[16] T. Radil, P. M. Ramos, F. M. Janeiro and A. Cruz Serra, "PQ Monitoring System for Real-Time Detection and Classification of Disturbances in a Single-Phase Power System," IEEE Transactions on Instrumentation and Measurement, Vol. 57, pp.1725-1733, 2008.
[17] L. M. Stancu and V. Dogaru-Ulieru, "Data Acquisitions in Systems Lighting," International Journal of Engineering Science and Innovative Technology (IJESIT),Volume 3, Issue 3, pp.73-78, May 2014.
[18] G. Vincent, S. Sasitharan, M. K. Mishra, and K. Karthikeyan, "A dsp-based integrated hardware set-up for a dstatcom: Design, development, and implementation issues," IETE JOURNAL OF RESEARCH, vol. 56(1), pp.11-21, 2010.
[19] R. Bitter, T. Mohiuddin, and M. Nawrocki, LabVIEW: Advanced programming techniques - SECOND EDITION, September, 2006.
[20] H. P. Halvorsen, Introduction to LabVIEW, March, 2014.
[21] J. Jovitha,Virtual Instrumentation Using Labview, January, 2010.
[22] K. N. Jadhav and N. Sarwade, "Comparative Review Study of 4-Channel Data Acquisition System using Lab VIEW," International Journal of Engineering Research & Technology, 2014.

Abstract:
This paper presents the virtual instrument used to monitor and analyze the behavior of Uninterruptible Power Supplies (UPS) system. The monitoring system includes: Hall effect sensors, data acquisition board, the LabVIEW environment and PC host. The applications enable the equipment to perform the functions of digital scope and analyze the following parameters: harmonic content, total harmonic distortion THD, RMS value, positive peak value, negative peak value. For consumers which include interference-sensitive equipment, using passive filters tuned to the frequency of the interference harmonics is recommended.

IJETSI is Member of